<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Laptop screen &#187; hp 367759-001 battery</title>
	<atom:link href="http://www.batteryorg.com/tag/hp-367759-001-battery/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.batteryorg.com</link>
	<description></description>
	<lastBuildDate>Fri, 03 Feb 2012 07:42:18 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.1.3</generator>
		<item>
		<title>Caution when you charge a battery</title>
		<link>http://www.batteryorg.com/2009/07/19/caution-when-you-charge-a-battery/</link>
		<comments>http://www.batteryorg.com/2009/07/19/caution-when-you-charge-a-battery/#comments</comments>
		<pubDate>Mon, 20 Jul 2009 03:49:44 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Uncategorized]]></category>
		<category><![CDATA[hp 367759-001 battery]]></category>
		<category><![CDATA[hp f2024a battery]]></category>
		<category><![CDATA[hp f2024b battery]]></category>
		<category><![CDATA[hp f4486b battery]]></category>
		<category><![CDATA[hp f4809a battery]]></category>
		<category><![CDATA[hp f4812a battery]]></category>

		<guid isPermaLink="false">http://www.batteryorg.com/?p=281</guid>
		<description><![CDATA[When charging a lead acid battery with over-voltage, current limiting must be applied once the battery starts to draw full current. Always set the current limit to the lowest practical setting and observe the battery voltage and temperature during the &#8230; <a href="http://www.batteryorg.com/2009/07/19/caution-when-you-charge-a-battery/">Continue reading <span class="meta-nav">&#8594;</span></a>]]></description>
			<content:encoded><![CDATA[<p>When charging a lead acid <a href="http://www.batteriesshop.co.uk/">battery</a> with over-voltage, current limiting must be applied once the battery starts to draw full current. Always set the current limit to the lowest practical setting and observe the <a href="http://www.iseekblog.com/batteryb/ ">battery</a> voltage and temperature during the procedure. If the battery does not accept a normal charge after 24 hours under elevated voltage, a return to normal condition is unlikely.</p>
<p>The price of the Hawker cell is slightly higher than that of the plastic equivalent, but lower than the NiCd. Also known as the ‘Cyclone’, this cell is wound similar to a cylindrical NiCd <a href="http://www.batteriesshop.co.uk/hp.html" target="_blank">hp laptop battery</a>. This construction improves the cell’s stability and provides higher discharge currents when compared to the flat plate SLA. Because of its relatively low self-discharge, Hawker cells are well suited for defibrillators that are used on standby mode.</p>
<p>Lead acid <a href="http://www.batteriesshop.co.uk/hp-f2024a.htm">hp f2024a battery</a> are preferred for UPS systems. During prolonged float charge, a periodic topping charge, also known as an ‘equalizing charge’, is recommended to fully charge the plates and prevent sulfation. An equalizing charge raises the battery voltage for several hours to a voltage level above that specified by the manufacturer. Loss of electrolyte through elevated temperature may occur if the equalizing charge is not administered correctly. Because no liquid can be added to the SLA and VRLA systems, a reduction of the electrolyte will cause irreversible damage. Manufacturers and service personnel are often divided on the benefit of the equalizing charge.</p>
<p>Some exercise, or brief periodic discharge, is believed to prolong <a href="http://www.batteriesshop.co.uk/hp-f2024b.htm">hp f2024b battery</a> life of lead acid systems. If applied once a month as part of an exercising program, the depth of discharge should only be about 10 percent of its total capacity. A full discharge as part of regular maintenance is not recommended because each deep discharge cycle robs service life from the battery.</p>
<p>More experiments are needed to verify the benefit of exercising lead acid <a href="http://www.batteriesshop.co.uk/hp-f4486b.htm">hp f4486b battery</a>. Again, manufacturers and service technicians express different views on how preventive maintenance should be carried out. Some experts prefer a topping charge while others recommend scheduled discharges. No scientific data is available on the benefit of frequent shallow discharges as opposed to fewer deep discharges or discharge pulses.</p>
<p>Disconnecting the float charge while the VRLA is on standby is another method of prolonging battery life. From time-to-time, a topping charge is applied to replenish the energy lost through self-discharge. This is said to lower cell corrosion and prolong <a href="http://www.batteriesshop.co.uk/hp-f4809a.htm">hp f4809a battery</a> life. In essence, the battery is kept as if it was in storage. This only works for applications that do not draw a load current during standby. In many applications, the <a href="http://www.batteriesshop.co.uk/hp-f4812a.htm">hp f4812a battery</a> acts as an energy buffer and needs to be under continuous charge.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.batteryorg.com/2009/07/19/caution-when-you-charge-a-battery/feed/</wfw:commentRss>
		<slash:comments>9</slash:comments>
		</item>
	</channel>
</rss>

